Earthquake and Its Cause

When rocks of the earth crust are suddenly disturbed , vibration are caused which spread in all direction from the place of disturbance. The passage of vibration through the rocks may induce a local and regional shaking in them and the shaking movement may last for various fraction of time.  is an earthquake.

Cause of Earthquake:-

  1. Tectonic earthquake:- It is broadly agreed that these are caused displacement of blocks of the rocks and according to H.F Reid theory any block on the earth that is under the influence of unequal forces withstand these force in initial stage by undergoes elastic deformation and the force get stored in the rocks as elastic strain till a limit but when the limit is exceed by operating forces. A fractures is caused at that stage in the block is a type of tectonic earthquake

  1. Non Tectonic Earthquake:- Due to volcanic eruption or collapse of ground
Focus & Epicenter detail:- The origin of a particular earthquake is termed as Focus and the point or place on the surface vertically above the focus of an earthquake is termed as Epicenter


EARTHQUAKE WAVES:-
  1. P waves:- Primary waves ( Push and pull)
  2. S waves ;- Secondary waves
  3. L waves (Surface waves) 


Intensity of Earthquake
  • People do not feel any earth movement if the value = <3.4 (Richter Scale Equivalent) 
  • Most Building collapse if Value is =  6.2 -7.9
  • Almost every thing is destroyed = >8.0 

INDIAN SEISMIC CODES
  1. IS ; 1893 ( Part-1), 2002 : Criteria for Earthquake Resistant Design of structure ( V th Revision)
  2. IS: 13920, 1993 : Ductile Detailing of Reinforced Concrete Structures subjected to seismic forces
  3. IS : 13827, 1993 : Guidelines for Improving Earthquake Resistant of earthen Building.
  4. IS 13828, 1993 : Indian standard for Repair and seismic strengthening of Building.
  5. SP : 22 ( S&T), 1982: Explanatory handbook on codes for earthquake Engineering. 



PRECAUTION WHILE DESIGNING THE EARTHQUAKE RESISTANT BUILDING
  • Roofs of the building should be light weight type because earthquake is a function of mass so the building shall be light as possible
  • Height of building in seismic zones IV and V only one storey
  • Shape of building -  For better earthquake resistant , the building should have a simple rectangular plan and be symmetrical as far as possible about both the areas.
  • Walls :- when a longer wall is required , the wall should be strengthed by intermedite vertical buttresses.
  • The width of the opening sholud not more than 1.20 m. and the sum of the width of opening in a wall should not exceed 33 % of total wall length 
  • Foundation;-The depth of foundation below existing ground level at least lie 400 mm.                           2. The footing should be built by using stone, fired brick using cement or lime mortar.       3. the wall above foundation should be constructed using stone or burnt brick laid in cement

Comments

Popular posts from this blog

Anti Termite Treatment, Pre & Post Construction Termite

A.T.T  is the treatment given to the structure to protect it against Attack by subterranean termites, using a suitable chemical. The   chemical barrier   is a layer of soil in contact with the structure that has been suitably treated with approve chemical, so as to form an impervious barrier to kill that termites The following procedure of anti termite treatment to be done at the project site are based on IS 6313: 2001 The surface of the ground should be clean, compacted and firm. it should be free from any organic impurities. Safety goggles,  gloves  and face mask should be readily available at the site. The person conducting the anti termite treatment should be trained and should be wearing all the above safety gear during the operation. preliminary moisturing should be done when the soil is Sandy, loose and porous because the chemical solution may be lost due to percolation. The chemical treatment of the soil should start only after the foundation trenches and pi

Waterproofing

Waterproofing has become the most basic need of today's Time. As you know, The old structures become damaged due to waterproofing leakage. If the Treatment of waterproofing becomes during Construction, then the best remains otherwise after completion very difficult to repair and we can avoid the following:- Efflorescence of Bricks Plaster Crumbling Corrosion of metal Warping and decay of timber Deterioration of floor covering Damage to electrical installations and short circutting Blistering,flaking and bleaching of paint. Development of termites Development of Unhealthy condition for the occupant of the building The leakage of water is most commonly in those area where we use continuous water like toilet, Kitchen , balconies and terrace etc . we can stop the leakage of these areas by following procedures ------ Waterproofing   :- The process of making a surface or a structure element impermeable, so that water does not pass through. It also be designed t

Knapen system of drying walls

Principle of  Knapen system : A difference of 16 °C to 24 °C is required to displace the vitiation air from a building by means of a vertical air shaft. The Knapen Tube : The method of fixing the Knapen tube in the wall. it is a simple porous tube which is fixed with its mouth inclined outwards. As the tubes are porous the moisture of penetrates inside them. Due to difference of temperature the dry air enters in the tube from its top portion as indicated by arrow. This dry air evaporates the moisture and saturated air comes out from the lower portion of the tube. This circulation of air is due to perfectly natural laws, and remains continuous till there is any moisture left in the wall.